Add to Cart
Three Zone Thermal Shock Test Chamber
Three-Zone Thermal Shock Test Chamber, also named as Temperature Shock Tester or High & Low Temperature Shock tester is used to assess the adaptability of the product to the sharp changes in ambient temperature. The identification test of equipment design and the routine test in the batch production phase are not allowed. These tests can also be used in environmental stress screening tests in some cases. Applicable to all kinds of electronic components, hardware appliances, plastic materials, automotive, medical, chemical, communications and other industries . The three-zone thermal shock test chamber is divided into three parts: High temperature zone, Low temperature zone and Sample Test zone. The product to be tested is placed in the Test zone. The temperature of the high temperature zone or the low temperature zone during the impact is automatically entered into the test zone according to the program for shock test. The product do not need to move.
The advantage of Three-zone thermal shock test chamber
1. the inner box material is made of national standard 1.2mm thick SUS#304 .
2. The main electronic circuit system are imported brands like Taiwan Dongyuan, Swiss Carlo, Japan Omron, good quality, long service life,
3. Advanced and reliable refrigeration and control system: French "Tecumseh" or semi-closed German "Bock" compressor,US Honeywell refrigerant,the US Sporlan PWM valve, Italy Castle , Danfoss of Denmark .
4. The humidification system pipeline is separated from the control circui,improve the safety.
5. The products have long-term , testing, calibration of internal temperature and humididty before delivery
Model |
JQTS3-50 |
JQTS3-80 |
JQTS3-100 |
JQTS3-150 |
JQTS3-225 |
JQTS3-408 |
JQTS3-800 |
JQTS3-1000 |
Inner size |
40*32*42 |
50*40*42 |
55*45*42 |
68*50*45 |
75*60*50 |
80*80*60 |
10*100*80 |
100*125*80 |
Outer size |
140*140*188 |
150*140*188 |
155*150*188 |
170*168*195 |
180*198*205 |
195*230*235 |
230*268*270 |
230*320*270 |
Capacity(L) |
50L |
80L |
100L |
150L |
225L |
408L |
800L |
1000L |
Weight(kg) N.W |
800 |
900 |
950 |
1050 |
1250 |
2800 |
3600 |
4500 |
Temp.Shock Range |
A:-40℃~180℃ B:-55℃~180℃ C:-65℃~180℃ |
|||||||
Shock type |
1. High Temp.→Low Temp. 3. Normal Temp →High Temp. →Normal Temp. →Low Temp. |
|||||||
High Temp.Chamber |
+60°C~+200°C |
|||||||
Pre-Heating Time |
(+20°C~200℃) <35 minutes |
|||||||
Low Temp.Chamber |
(-40°C/-55°C/-65°C) ~ -10°C |
|||||||
Pre-cooling Time |
(+20°C~-75℃ )< 60minutes |
|||||||
Temperature |
‘-40℃/-55°C/-65℃~+180℃ <5 second (Two Zone) |
|||||||
Recover time |
Heat chamber Exposure 30min |
|||||||
Cold chamber Exposure 30 min |
||||||||
within 5~10min |
||||||||
Temp.fluctuation range |
±0.5℃ |
|||||||
Chamber material |
Outer shell : standard 1.5mm electrolytic plate Baked electrostatic painting |
|||||||
Insulation material |
|
|||||||
Controller |
7'LCD colorful Chinese and English touch screen (10 inch optional ),Program or fix setting , 120sets programs ,1200steps USB ,RS232 /R485 interface ,mobile APP , computer connection remote control (optional network interface ) |
|||||||
Control system |
|
|||||||
Cooling type |
Semi-closed two-stage compressor (water cooled) |
|||||||
Refrigerant |
HFC-404a and HFC23 /HFC-R449A/HFC-507 |
|||||||
Compressor |
Fully closed French “Tecumseh “compressor |
|||||||
Safety protection device |
Fuse free switch, compressor high and low voltage protection switch,Over-temperature potector, |
|||||||
Spare parts |
Glass viewing window , two shelves , 2*¢50mm cable Ports ,Casters , |
|||||||
Power Supply |
AC/380V,50HZ,20~50A, |