Advanced Temperature and Humidity Chamber for Reliable Product Testing
An environmental chamber, also called a climatic chamber or climate chamber, is an enclosure used to test the effects of specified environmental conditions on biological items, industrial products, materials, and electronic devices and components.
Such a chamber can be used:
An environmental test chamber artificially replicates conditions which machinery, materials, devices or components might be exposed to. It is also used to accelerate the effects of exposure to the environment, sometimes at conditions not actually expected.
Chamber testing involves testing and exposing products to various environmental conditions in a controlled setting. Climatic Chamber testing and Thermal Shock testing are part of chamber testing. Climatic Chamber testing is a broad category of ways to simulate climate or excessive ambient conditions exposure for a product or a material under laboratory-controlled yet accelerated conditions. On the other hand, Thermal Shock testing is used to simulate how materials will react when exposed to changes in extreme climatic conditions, such as going from extremely cold to extremely hot conditions in a very short period of time (usually only few seconds).
These conditions may include:[1]
Manufactured samples, specimens, or components are placed inside the chamber and subjected to one or more of these environmental parameters to determine reliability or measure after-effects such as corrosion. In the case of machinery such as internal combustion engines, byproducts such as emissions are monitored.
An environmental chamber can be a small room used both to condition test specimens and to conduct the test. It can be a smaller unit that's used for conditioning test items. Also, some chambers are small enough to be placed onto a universal testing machine or other test apparatus.
Many chambers are set at a certain set of conditions. Others can be programmed to cycle through specified sequences of conditions.
As test requirements may be relatively simple or complex, environmental test chambers vary widely in size, ranging from small units designed for placement on bench tops to large walk-in chambers. Test chambers generally have viewports or video feeds to allow for visual inspection of the sample during the test. Reach-in chambers provide an opening that technicians may use to handle test samples. Chambers providing interior visual lighting must take into account the heat generated and compensate accordingly.
As with the wide variance in size, a number of user control options are available, ranging from simple analog indicators up to more modern digital readouts with LCD displays. Chambers may be computer programmable, and networked or Web-enabled test chambers with built in web servers are also available.
Several standards organizations provide standards and guidance on environmental test chamber construction, temperature control standards, and engineering tolerances.
Standard Features
v Extremely low noise level
v Low energy consumption
v Safety to test specimens thanks to independent temperature measurement
v Easy to clean stainless steel test space
v Wide humidity range-extreme climate
v Stainless steel 304#1.2mm internally With outernal steel with polymer coating
v Energy-efficient refrigeration with exclusive eletronic expansion valve system
v Specialized humidity generation and control
v Unique thermal break construction for extreme testing
v 3" cable port,two shelf & casters included
v New USB port for uploading and down-loading programs and test data.
v 7"/10” imported “DELTA” touch screen controller
v Optional APP and WLAN port for attached with PC,remote data and programming anywhere, anytime.
v English interface
Corresponding standard
Model | JQTH-100 | JQTH-150 | JQTH-225 | JQTH-408 | JQTH-800 | JQTH-1000 | JQTH-1200 | JQTH-1500 | |
Volume (L) | 100L | 150L | 225L | 408L | 800L | 1000L | 1200L | 1500L | |
Inner size (cm) | W | 50 | 50 | 70 | 70 | 100 | 100 | 150 | 150 |
D | 40 | 50 | 46 | 75 | 80 | 100 | 80 | 100 | |
H | 50 | 60 | 70 | 80 | 100 | 100 | 100 | 100 | |
Outer size (cm) | W | 70 | 70 | 90 | 90 | 120 | 120 | 200 | 200 |
D | 125 | 135 | 157 | 188 | 185 | 205 | 135 | 155 | |
H | 157 | 167 | 185 | 195 | 215 | 215 | 215 | 215 | |
Temp range | Model S:-70°C~+150°C , Model L: -40°C~+150°C or customized. | ||||||||
Exterior material | Standard 1.5mm Electrolytic plate with Electrostatic painting | ||||||||
Interior material | Matte Stainless steel plate SUS 304 | ||||||||
Insulation material | Rigid Polyurethane Foam and Glass Fiber Wool | ||||||||
Refreigeration system | Hermetric Compressor ,Cascsde Refrigeration CFC free refrigeration system , HFC-R404A/HFC-23/HFC-R449 /HFC-507 | ||||||||
Control method | PWM control | ||||||||
Working conditions | RT to 35℃ | ||||||||
Humidity range | 10 % to 98% RH 10 %~ 98% RH | ||||||||
Temp fluctuation | ±0.5℃(No-load) | ||||||||
Temp uniformity | ±2℃(No-load) | ||||||||
Temp cooling rate | +150°C ~-70°C ,0.8°C~ 1℃/min (Non-Linear) | ||||||||
Temp rising rate | -70°C~+150°C , 1°C~3℃/ min (Non-Linear) | ||||||||
Controller | TW DELTA PLC,7 "color touch screen control Chinese,English,Russian menu Operation Model :Setting Fix /Program | ||||||||
Standard Accessories | Observation Window *1,Cable Port (¢50mm*2),Shelves*2 ,Chamber lamp*1,Power cable 2m | ||||||||
Safety device | No-Fuse Breaker,Over -pressure,Over-load and Over-current protector for compressor ,Over-Temp,Protector Over-voltage coolant protector ,Overload protector for fan, Dry heat protector and Fault warning system , short of water protector | ||||||||
Configuration interface | With USB , WLAN, RS232 or R485 port , APP function is optional | ||||||||
Power | 5.5KW | 6KW | 8.5KW | 9KW | 13.5KW | 15KW | 17KW | 18KW | |
Weight (kg) | 300 | 360 | 430 | 530 | 780 | 890 | 1100 | 1380 | |
Power supply | AC 220V or AC380V 50Hz 3 PHASE ,Ground wire |